Brief Blue Waters System Overview

Blue Waters

Blue Waters is a Cray XE6/XK7 system consisting of more than 22,500 XE6 compute nodes (each containing two AMD Interlagos processors) augmented by more than 4200 XK7 compute nodes (each containing one AMD Interlagos processor and one NVIDIA GK110 "Kepler" accelerator) in a single Gemini interconnection fabric. This configuration enables extremely large simulations on hundreds of thousands of traditional CPUs for science and engineering discovery, while also supporting development and optimization of cutting-edge applications capable of leveraging the compute power of thousands of GPUs.

Blue Waters Nodes

Blue Waters is equipped with three node types: traditional compute nodes (XE6), accelerated compute nodes (XK7), and service nodes. Each node type is introduced below.

Traditional Compute Nodes (XE6)

The XE6 dual-socket nodes are populated with 2 AMD Interlagos model 6276 CPU processors (one per socket) with a nominal clock speed of at least 2.3 GHz and 64 GB of physical memory. The Interlagos architecture employs the AMD Bulldozer core design in which two integer cores share a single floating point unit. In describing Blue Waters, we refer to the Bulldozer compute unit as a single compute "core" and consider the Interlagos processors as having 8 (floating point) cores each, although this processor has been described elsewhere as having 16 cores.  The Bulldozer core has 16KB/64KB data/instruction L1 caches, 2 MB shared L2 and instruction support for SSSE3, SSE4.1, SSE4.2, AES-NI, PCLMULQDQ , AVX, XOP, and FMA4. Each core is able to complete up to 8 floating point operations per cycle. The architecture supports 8 cores per socket with two die, each die containing 4 cores forming a NUMA domain. The 4 cores of a NUMA domain share an 8 MB L3 cache.  Access times for shared memory on the other die in the same socket are somewhat longer than access times within the same die. See chapters 1 and 2 in the AMD document Software Optimization Guide for AMD Family 15hProcessors for additional technical information on the 62xx processor.

GPU-enabled Compute Nodes (XK7)

Accelerator nodes will be equipped with one Interlagos model 6276 CPU processor and one NVIDIA GK110 "Kepler" accelerator K20X. The CPU acts as a host processor to the accelerator.  Currently the NVIDIA accelerator will not directly interact with the Gemini interconnect so that data needs to be moved to a node containing an accelerator, and that data may be accessed by the accelerator as mapped memory, or through DMA transfers to accelerator device memory. Each XK7 node has 32 GB of system memory while the accelarator has 6 GB of memory. The Kepler GK110 implementation includes 14 Streaming Multiprocessor (SMX) units and six 64?bit memory controllers. Each of the SMX units feature 192 single?precision CUDA cores. The Kepler architecture supports a unified memory request path for loads and stores, with an L1 cache per SMX multiprocessor. Each SMX has 64 KB of on?chip memory that can be configured as 48 KB of Shared memory with 16 KB of L1 cache, or as 16 KB of shared memory with 48 KB of L1 cache. The Kepler also features 1536KB of dedicated L2 cache memory. Single?Error Correct Double?Error Detect (SECDED) ECC code is enabled by default.

The Cray XK currently supports exclusive mode for access to the accelerator. NVIDIA's Proxy (part of "Hyper-Q") manages access for other contexts or multiple tasks of the user application via the CRAY_CUDA_MPS (formerly CRAY_CUDA_PROXY) environment setting.

I/O and Service Nodes (XIO)

Each Cray XE6/XK6 XIO blade contains four service nodes. Service nodes use AMD Opteron "Istanbul" six-core processors, with 16 GB of DDR2 memory, and the same Gemini interconnect processors as compute nodes. XIO nodes take one of four roles as Service nodes:

  • esLogin Nodes: These nodes provide user access and log in services for the system. Login nodes are network attached esLogin servers. Users access the system through these nodes, each running the full Linux operating system.
  • PBS MOM Nodes: These are nodes which run the jobs (where the PBS script gets executed and aprun is launched) and where interactive batch jobs (qsub -I) place a user. These nodes are in the Gemini high speed network (HSN).
  • Network Service Node: Each Network service node contains one Infiniband QDR IB card that can be connected to external networking connections.
  • LNET Router Nodes: Manage file system metadata and transfer data to and from storage devices and applications. These nodes use Infiniband QDR cards as the interface to the storage network.
  • Boot Node/System Database Node (SDB): Each Cray XE6/XK6 system requires one or more boot node and one or more SDB node. These nodes contain one 4-Gbit FC HBA and one GigE PCIe card. The FC HBA connects to the RAID and the GigE card connects to the System Management Workstation of the HSS. A redundant boot and SDB node are also configured to provide resiliency.

Interconnect

The Blue Waters system employs the Cray Gemini interconnect, which implements a 3D torus topology. Note that there are 2 compute nodes per gemini hub. The torus is periodic or re-entrant in all directions (paths wrap around). A schematic of the general use of the hish speed network (HSN) is shown in the following figure detailing a simplified view of the location of all node types in the torus. In reality the IO and service nodes are not confined to a single "plane" in the torus.

The (x,y,z) locations of the Gemini routers can be plotted to show a particular view of the torus. In the image below the Blue Waters torus is shown with gray dots representing the location of XE nodes, red spheres representing the location of XK nodes and blue spheres representing service nodes. Note that the system should be viewed as periodic or re-entrant and that there is no unique origin and no corners in a torus.

The native messaging protocol for the interconnect is Cray's Generic Network Interface (GNI). A second messaging protocol, the Distributed Shared Memory Application (DMAPP) interface, is also supported. GNI and DMAPP provide low-level communication services to user-space software. GNI directly exposes the communications capabilities of the  Gemini while DMAPP supports a logically shared, distributed memory (DM) programming model and provides remote memory access (RMA) between processes within a job in a one-sided manner. For more information please see the Using the GNI and DMAPP APIs document.

Data Storage

Online storage

Blue Waters will provide three different file systems built with the Lustre file system technology.

The three file systems are provided to the users as follows:

  • /u – storage for home directories
  • /projects – storage for project home directories
  • /scratch – high performance, high capacity transient storage for applications

All three file systems on Blue Waters will be built using Cray Sonexion 1600 Lustre appliances. The Cray Sonexion 1600 appliances provide the basic storage building block for the Blue Waters I/O architecture and are referred to as a "Scalable Storage Unit" (SSU). Each SSU is RAID protected and is capable of providing up to 5.35 GB/s of IO performance and ~120TB of usable disk space.

The /u and /projects are configured with 18 (eighteen) SSUs each, to provide 2 PB usable storage and 96 GB/s IO performance.

The /scratch file system uses 180 (one hundred eighty) SSUs to provide 21.6PB of usable disk storage and 963 GB/s IO performance. This file system can provide storage for up to 2 million file system objects.

Nearline storage

The Blue Waters Nearline storage environment provides 350PB of tape storage. The Nearline storage environment currently has 1.2PB of disk cache running on DDN hardware and 244 IBM TS1140 tape drives distributed among four SpectraLogic tape libraries. The system will expand to more than 300 tape drives providing more than 350 PB later this year.

Usage Guidelines

Blue Waters uses a one-time password system for loging into accounts based on RSA SecureIDs. You will receive an RSA token when your account is set up.

Queues and quotas discussed in the User Guide.

Compiling and Linking

The Blue Waters development environment include three compiler suites:

  • Cray Compilation Environment (CCE) : PrgEnv-cray
  • PGI Compiler Suite : PrgEnv-pgi
  • GNU Compilers : PrgEnv-gnu

The default programming environment is the Cray (PrgEnv-cray) compiler suite. Other compilers may be selected using the module swap command with either PrgEnv-pgi or PrgEnv-gnu.

The programming environments provide wrappers for compiling Fortran (ftn), C (cc), or C++ (CC) programs, so that similar compiler commands can be used no matter which compiler environment is selected. These wrapper scripts also check for the presense of other loaded modules and take the appropriate measures to add include paths and libraries with compiling and linking.

See the Compiling page in the User Guide for more information.

Reference